Network Code / CNE

For Load Centers (industrial and commercial users in Medium and High Voltage) and Supply/Generation Plants, compliance is not optional and requires a structured approach.

This is the fundamental analytical stage to assess the current state of the facility and detect compliance gaps.

  • Power Quality Studies: Point of Connection (PCC) measurement in accordance with the requirements of the Grid Code (frequency, voltage, harmonic distortion, voltage fluctuation/flicker and current imbalance).
  • Power Flow and Power Factor Studies: Simulation of system behavior to design solutions that guarantee a power factor between 0.95 and 1.0 with five-minute measurement.
  • Short Circuit Studies and Protection Coordination: Evaluation of the equipment's ability to withstand faults and adjustment of relays to ensure selective isolation of disturbances.
  • Arc Flash Study (Arc Flash Risk): Determination of incident energy for the safety of operating personnel, implicitly required in the management of electrical infrastructure.

Diagrama explicativo de la fase de diagnóstico y cumplimiento técnico que abarca cuatro estudios eléctricos: calidad de la energía, flujo y factor de potencia, cortocircuito y coordinación de protecciones, y análisis de Arc Flash

If the diagnosis reveals non-compliance, the optimal technical solutions are designed based on cost-benefit criteria.

  • Design of Reactive Power Compensation Systems: Technical specification of automatic capacitor banks, harmonic filters (active or passive) or STATCOM systems for voltage and power factor control.
  • Modernization of Control and Monitoring Systems: Design and integration of continuous power quality monitoring systems with reporting compatible with the requirements of the CRE and CENACE.
  • Detailed Engineering for Infrastructure: Plans, updated single-line diagrams and specifications for the interconnection or modification of substations.
Infografía sobre diagnóstico y diseño de soluciones técnicas: compensación de reactivos, monitoreo para CRE y CENACE, e ingeniería de detalle

Technical compliance must be formalized legally and administratively.

  • Development of the Network Code Work Plan: Structuring the official document submitted to the CRE, detailing the actions, technical justifications and the execution schedule to remedy the non-compliance.
  • Interconnection/Connection Procedure Management: Comprehensive support for new load centers or power plants in the processes of the CRE platform and the CENACE units.
  • Preventive Regulatory Audits: Review of legal status, supply contracts and connection agreements to identify risks of financial penalties (which can range from 2% to 10% of the previous year's gross income).
Diagrama de tres pilares del cumplimiento técnico energético: Elaboración de plan de trabajo, trámites de interconexión con CRE y CENACE, y auditorías regulatorias preventivas

Formal validation that the facilities comply with current regulations.

  • Coordination with Inspection Units (UI): Management and support during inspection visits of the CRE-accredited Units to obtain the approval opinion.
  • Commissioning Tests: Monitoring and validation that the installed mitigation equipment functions exactly according to the designed and approved parameters.
Validación formal del cumplimiento normativo: Coordinación con Unidades de Inspección acreditadas por la CRE para dictamen aprobatorio, y Pruebas de Puesta en Servicio (Commissioning) para verificar equipos de mitigación

Value-added services for managers and operations committees.

  • Financial Impact Analysis and Return on Investment (ROI): Economic evaluation of Grid Code projects, considering the mitigation of fines, bonuses for power factor and energy efficiency.
  • Technical and Regulatory Training: Tailor-made courses and workshops for maintenance and operations personnel on the operational implications of Grid Code 2.0 (or current versions).
  • Post-Compliance Monitoring and Support: Ongoing consulting services (SaaS or support policies) to analyze electrical system alerts and prevent future deviations due to changes in the operation of the CFE plant or network.
Servicios de valor agregado para directivos: 1. Análisis de impacto financiero y ROI, 2. Capacitación técnica y regulatoria, y 3. Monitoreo y soporte post-cumplimiento