{"id":2246,"date":"2026-08-16T11:56:44","date_gmt":"2026-08-16T17:56:44","guid":{"rendered":"https:\/\/jarrstech.com\/?p=2246"},"modified":"2026-09-10T16:37:10","modified_gmt":"2026-09-10T22:37:10","slug":"blindando-la-industria","status":"publish","type":"post","link":"https:\/\/jarrstech.com\/en\/blindando-la-industria\/","title":{"rendered":"Protecting the industry"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Cybersecurity Strategies in TO\/SCADA Environments<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">We begin with an infographic about the basic components and vulnerabilities in the industry. And we use the example of pipelines that can carry gas or oil. <\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/jarrstech.com\/wp-content\/uploads\/2026\/08\/infografia-de-ductos-1024x1024.png\" alt=\"Diagrama del sistema de ductos en EE. UU., mostrando sus componentes, rutas de distribuci\u00f3n y vulnerabilidades ante ataques f\u00edsicos y cibern\u00e9ticos\" class=\"wp-image-2255\" srcset=\"https:\/\/jarrstech.com\/wp-content\/uploads\/2026\/08\/infografia-de-ductos-1024x1024.png 1024w, https:\/\/jarrstech.com\/wp-content\/uploads\/2026\/08\/infografia-de-ductos-300x300.png 300w, https:\/\/jarrstech.com\/wp-content\/uploads\/2026\/08\/infografia-de-ductos-150x150.png 150w, https:\/\/jarrstech.com\/wp-content\/uploads\/2026\/08\/infografia-de-ductos-768x768.png 768w, https:\/\/jarrstech.com\/wp-content\/uploads\/2026\/08\/infografia-de-ductos-12x12.png 12w, https:\/\/jarrstech.com\/wp-content\/uploads\/2026\/08\/infografia-de-ductos.png 1254w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<center><figure class=\"wp-block-image size-large\"><figure><img decoding=\"async\" width=\"572\" height=\"1024\" data-src=\"https:\/\/jarrstech.com\/wp-content\/uploads\/2026\/08\/Los_4_Pilares_Ciberseguridad_OT-572x1024.png\" alt=\"Los 4 pilares de la ciberseguridad OT: diferenciaci\u00f3n IT vs. OT, defensa de sistemas legados, protecci\u00f3n de la cadena de suministro USB y visibilidad centralizada con integraci\u00f3n XDR\" class=\"wp-image-2256 lazyload\" data-srcset=\"https:\/\/jarrstech.com\/wp-content\/uploads\/2026\/08\/Los_4_Pilares_Ciberseguridad_OT-572x1024.png 572w, https:\/\/jarrstech.com\/wp-content\/uploads\/2026\/08\/Los_4_Pilares_Ciberseguridad_OT-167x300.png 167w, https:\/\/jarrstech.com\/wp-content\/uploads\/2026\/08\/Los_4_Pilares_Ciberseguridad_OT-768x1376.png 768w, https:\/\/jarrstech.com\/wp-content\/uploads\/2026\/08\/Los_4_Pilares_Ciberseguridad_OT-857x1536.png 857w, https:\/\/jarrstech.com\/wp-content\/uploads\/2026\/08\/Los_4_Pilares_Ciberseguridad_OT-1143x2048.png 1143w, https:\/\/jarrstech.com\/wp-content\/uploads\/2026\/08\/Los_4_Pilares_Ciberseguridad_OT-7x12.png 7w, https:\/\/jarrstech.com\/wp-content\/uploads\/2026\/08\/Los_4_Pilares_Ciberseguridad_OT-scaled.png 1429w\" data-sizes=\"(max-width: 572px) 100vw, 572px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 572px; --smush-placeholder-aspect-ratio: 572\/1024;\" \/><\/figure><\/figure><\/center>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>1. Context and Technical Differentiation (IT vs. OT)<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Security in industrial environments differs significantly from traditional computer science (IT). While an IT attack primarily affects the availability of data or digital services, a compromise in <strong>OT directly impacts physical operations<\/strong>, potentially causing the shutdown of production lines, environmental damage, or risks to the physical integrity of people.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Industrial environments present unique technical challenges:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Proprietary Protocols:<\/strong> They use specific communication languages (such as Modbus or Melsec) that IT tools often do not interpret correctly, leading to false positives or operational interruptions.<\/li>\n\n\n\n<li><strong>Legacy Systems:<\/strong> It is common to find equipment that is 10 to 20 years old and has outdated operating systems that no longer receive security patches, but are critical for operation.<\/li>\n\n\n\n<li><strong>Performance Restrictions:<\/strong> Industrial devices typically have limited memory and CPU resources, which prevents the use of heavy security agents.<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"559\" data-src=\"https:\/\/jarrstech.com\/wp-content\/uploads\/2026\/08\/it-vs-ot-1024x559.jpg\" alt=\"Comparaci\u00f3n entre TI (mundo digital) en flujo de datos y TO (mundo f\u00edsico) con incidentes, riesgos a operarios y maquinaria\" class=\"wp-image-2253 lazyload\" data-srcset=\"https:\/\/jarrstech.com\/wp-content\/uploads\/2026\/08\/it-vs-ot-1024x559.jpg 1024w, https:\/\/jarrstech.com\/wp-content\/uploads\/2026\/08\/it-vs-ot-300x164.jpg 300w, https:\/\/jarrstech.com\/wp-content\/uploads\/2026\/08\/it-vs-ot-768x419.jpg 768w, https:\/\/jarrstech.com\/wp-content\/uploads\/2026\/08\/it-vs-ot-18x10.jpg 18w, https:\/\/jarrstech.com\/wp-content\/uploads\/2026\/08\/it-vs-ot.jpg 1408w\" data-sizes=\"(max-width: 1024px) 100vw, 1024px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 1024px; --smush-placeholder-aspect-ratio: 1024\/559;\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>2. Technical Defense Strategies<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Network Defense and Microsegmentation:<\/strong> Solutions are implemented <strong>Deep Package Inspection (DPI)<\/strong> Designed to understand industrial protocols, these tools allow for the application of <strong>virtual patching<\/strong>, Protecting vulnerable systems against zero-day exploits without needing to shut down the machine to install software updates. Network security devices must offer low latency and technology of <em>bypass<\/em> to ensure that production does not stop even if the safety device fails.<\/li>\n\n\n\n<li><strong>Zero-Impact Endpoint Protection:<\/strong> For assets where software can be installed, ultra-lightweight agents are used that <strong>they do not require a system restart<\/strong> For its implementation, a critical factor in plants that operate continuously. These agents focus on:\n<ul class=\"wp-block-list\">\n<li><strong>Application blocking (<\/strong><strong>Lockdown<\/strong><strong>):<\/strong> They only allow the execution of processes authorized for industrial control.<\/li>\n\n\n\n<li><strong>Anomaly detection:<\/strong> They identify unusual behaviors in the operation that could indicate a compromise.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>Agentless Security Inspection (Portable):<\/strong> For systems where software cannot be installed (due to warranty void or network isolation), portable hardware devices are used to perform the <strong>malware scanning and removal<\/strong> <strong>in situ<\/strong> using its own processing resources so as not to affect the performance of the industrial asset.<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"1024\" data-src=\"https:\/\/jarrstech.com\/wp-content\/uploads\/2026\/08\/estrategias-defensa.jpg\" alt=\"Arquitectura de red industrial con gateway DPI y filtrado de tr\u00e1fico de protocolos para proteger la planta contra amenazas\" class=\"wp-image-2254 lazyload\" data-srcset=\"https:\/\/jarrstech.com\/wp-content\/uploads\/2026\/08\/estrategias-defensa.jpg 1024w, https:\/\/jarrstech.com\/wp-content\/uploads\/2026\/08\/estrategias-defensa-300x300.jpg 300w, https:\/\/jarrstech.com\/wp-content\/uploads\/2026\/08\/estrategias-defensa-150x150.jpg 150w, https:\/\/jarrstech.com\/wp-content\/uploads\/2026\/08\/estrategias-defensa-768x768.jpg 768w, https:\/\/jarrstech.com\/wp-content\/uploads\/2026\/08\/estrategias-defensa-12x12.jpg 12w\" data-sizes=\"(max-width: 1024px) 100vw, 1024px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 1024px; --smush-placeholder-aspect-ratio: 1024\/1024;\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>3. Supply Chain Management and External Risks<\/strong> <\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">One of the most critical attack vectors is the use of USB devices infected by vendors or employees. The technical strategy includes the use of <strong>sanitizing stations<\/strong> to validate and clean external devices before they are connected to the isolated industrial network.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"1024\" data-src=\"https:\/\/jarrstech.com\/wp-content\/uploads\/2026\/08\/gestion-suministros.jpg\" alt=\"Trabajador insertando una USB en un quiosco de desinfecci\u00f3n y an\u00e1lisis de amenazas en un entorno industrial\" class=\"wp-image-2257 lazyload\" data-srcset=\"https:\/\/jarrstech.com\/wp-content\/uploads\/2026\/08\/gestion-suministros.jpg 1024w, https:\/\/jarrstech.com\/wp-content\/uploads\/2026\/08\/gestion-suministros-300x300.jpg 300w, https:\/\/jarrstech.com\/wp-content\/uploads\/2026\/08\/gestion-suministros-150x150.jpg 150w, https:\/\/jarrstech.com\/wp-content\/uploads\/2026\/08\/gestion-suministros-768x768.jpg 768w, https:\/\/jarrstech.com\/wp-content\/uploads\/2026\/08\/gestion-suministros-12x12.jpg 12w\" data-sizes=\"(max-width: 1024px) 100vw, 1024px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 1024px; --smush-placeholder-aspect-ratio: 1024\/1024;\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>4. Visibility and Centralized Management (XDR Industrial)<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"> Technological convergence demands that telemetry and event logs in the OT world be integrated into platforms of <strong>Extended Detection and Response (XDR)<\/strong>. This allows for the correlation of attacks that originate in the IT environment (such as phishing) and that seek to make lateral movements towards the process control network.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"1024\" data-src=\"https:\/\/jarrstech.com\/wp-content\/uploads\/2026\/08\/visivilidad-.jpg\" alt=\"Tres operadores monitoreando tableros de ciberseguridad en un centro de control de XDR Industrial\" class=\"wp-image-2261 lazyload\" data-srcset=\"https:\/\/jarrstech.com\/wp-content\/uploads\/2026\/08\/visivilidad-.jpg 1024w, https:\/\/jarrstech.com\/wp-content\/uploads\/2026\/08\/visivilidad--300x300.jpg 300w, https:\/\/jarrstech.com\/wp-content\/uploads\/2026\/08\/visivilidad--150x150.jpg 150w, https:\/\/jarrstech.com\/wp-content\/uploads\/2026\/08\/visivilidad--768x768.jpg 768w, https:\/\/jarrstech.com\/wp-content\/uploads\/2026\/08\/visivilidad--12x12.jpg 12w\" data-sizes=\"(max-width: 1024px) 100vw, 1024px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 1024px; --smush-placeholder-aspect-ratio: 1024\/1024;\" \/><\/figure>","protected":false},"excerpt":{"rendered":"<p>Technical strategies and critical considerations for the protection of operational technology (OT) environments and industrial control systems (SCADA), based on technical information <\/p>","protected":false},"author":2,"featured_media":2266,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_robots_imageindex":"","_seopress_robots_snippet":"","_seopress_robots_primary_cat":"","_seopress_robots_breadcrumbs":"","_seopress_robots_freeze_modified_date":"","_seopress_robots_custom_modified_date":"","_seopress_robots_canonical":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_fb_img":"","_seopress_social_fb_img_attachment_id":0,"_seopress_social_fb_img_width":0,"_seopress_social_fb_img_height":0,"_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_seopress_social_twitter_img":"","_seopress_social_twitter_img_attachment_id":0,"_seopress_social_twitter_img_width":0,"_seopress_social_twitter_img_height":0,"_seopress_redirections_value":"","_seopress_redirections_enabled":"","_seopress_redirections_enabled_regex":"","_seopress_redirections_logged_status":"","_seopress_redirections_param":"","_seopress_redirections_type":0,"_seopress_analysis_target_kw":"Industria,seguridad,ciberseguridad","_eb_attr":"","wpai_generated_summary":"","footnotes":""},"categories":[11],"tags":[13],"class_list":["post-2246","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articulo","tag-mexico"],"acf":[],"_links":{"self":[{"href":"https:\/\/jarrstech.com\/en\/wp-json\/wp\/v2\/posts\/2246","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/jarrstech.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/jarrstech.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/jarrstech.com\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/jarrstech.com\/en\/wp-json\/wp\/v2\/comments?post=2246"}],"version-history":[{"count":10,"href":"https:\/\/jarrstech.com\/en\/wp-json\/wp\/v2\/posts\/2246\/revisions"}],"predecessor-version":[{"id":2326,"href":"https:\/\/jarrstech.com\/en\/wp-json\/wp\/v2\/posts\/2246\/revisions\/2326"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/jarrstech.com\/en\/wp-json\/wp\/v2\/media\/2266"}],"wp:attachment":[{"href":"https:\/\/jarrstech.com\/en\/wp-json\/wp\/v2\/media?parent=2246"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/jarrstech.com\/en\/wp-json\/wp\/v2\/categories?post=2246"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/jarrstech.com\/en\/wp-json\/wp\/v2\/tags?post=2246"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}